<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>47610</ErrorNumber>
<ErrorFamily>Media Handler (APL)</ErrorFamily>
<ErrorMessage>
MDHAPL: &lt;I/O name&gt; vacuum timeout:  Failed to achieve vacuum threshold (&lt;Threshold&gt;) (only reached &lt;ActualValue&gt;).
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
A timeout occurred while waiting for the specified vacuum to cross the threshold.
</text></DescriptionText>
<DescriptionText><text>
This error will generally come up while trying to pick a slipsheet on either the
picker or the pusher.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
A device error has occurred:
</text></DescriptionText>
<DescriptionText><text>
You may be able to continue by pressing the "resume" button onscreen (if present)
or by resetting the device and workstation.
</text></DescriptionText>
<DescriptionText><text>
For support under your service contract, contact the Creo Response Center at 1-(800) 472-2727
or online at http:\\eCentral.creo.com (or your local service representative)
</text></DescriptionText>
<DescriptionText><text>
To speed troubleshooting, please make a note of error numbers, the media type/size
and any information about the workflow or job that might be relevant.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Incorrect threshold value
</Cause>
<Cause>
Missing slipsheet
</Cause>
<Parameter>
I/O name -
This is the standard firmware name of the sensor.
</Parameter>
<Parameter>
Threshold -
This is the threshold value that was not reached.
</Parameter>
<Parameter>
ActualValue -
This is the actual value reached after the timeout.
</Parameter>
<LastModified>
22-Mar-2005
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:52 2008 PST
</Updated>
<Links>
</Links>
</Error>